<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hypervisor.fr &#187; VSAN</title>
	<atom:link href="http://www.hypervisor.fr/?cat=335&#038;feed=rss2" rel="self" type="application/rss+xml" />
	<link>http://www.hypervisor.fr</link>
	<description>French Bare-Metal weblog</description>
	<lastBuildDate>Wed, 26 Jun 2024 22:42:28 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Dual vSAN Datastores</title>
		<link>http://www.hypervisor.fr/?p=5949</link>
		<comments>http://www.hypervisor.fr/?p=5949#comments</comments>
		<pubDate>Thu, 15 Apr 2021 19:24:23 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[HowTo]]></category>
		<category><![CDATA[Tips & Tricks]]></category>
		<category><![CDATA[VMware]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[PowerCLI]]></category>
		<category><![CDATA[SVMotion]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5949</guid>
		<description><![CDATA[MAJ 30/07/2021 : Sur vSphere 7.0 U2 il est nécessaire de préciser l&#8217;UUID du cluster vSAN dans la commande, très probablement pour le fonctionnement d&#8217;HCI mesh :

Datastore UUID is required when a cluster UUID is specified


Get-VMHost&#124;%{($_&#124;get-esxcli).vsan.datastore.add($null, &#34;vsanDatastore2&#34;, &#34;11111111-1111-1111-1111-111111111111&#34;)}
En utilisant $null pour la propriété ClusterUUID, ca passe crème.
MAJ 18/05/2021 : On me signale dans l&#8217;oreillette que [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;"><em><span style="color: #ff0000;"><strong>MAJ 30/07/2021</strong></span> : Sur vSphere 7.0 U2 il est nécessaire de préciser l&#8217;UUID du cluster vSAN dans la commande, très probablement pour le fonctionnement d&#8217;HCI mesh :</em></p>
<blockquote>
<p style="text-align: justify;">Datastore UUID is required when a cluster UUID is specified</p>
</blockquote>
<p style="text-align: center;"><a href="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/dual_vsan_vsp7U2.png" target="_blank"><img class="aligncenter" src="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/dual_vsan_vsp7U2.png" alt="" width="549" height="500" /></a></p>
<pre class="brush: powershell; title: ; notranslate">Get-VMHost|%{($_|get-esxcli).vsan.datastore.add($null, &quot;vsanDatastore2&quot;, &quot;11111111-1111-1111-1111-111111111111&quot;)}</pre>
<p style="text-align: justify;">En utilisant $null pour la propriété ClusterUUID, ca passe crème.</p>
<p style="text-align: justify;"><em><span style="color: #ff0000;"><strong>MAJ 18/05/2021</strong></span> : On me signale dans l&#8217;oreillette que <strong>VMware supporterai officiellement cette méthode</strong> :</em></p>
<blockquote>
<p style="text-align: justify;"><em>Engineering have advised that the procedure you are carrying out is applicable to your specific need and is considered supported from us</em></p>
</blockquote>
<p style="text-align: justify;">Tous les admin VMware le savent, <strong>après renommage d&#8217;une VM</strong> il convient de faire un petit <strong>Storage vMotion</strong> (<a href="https://kb.vmware.com/s/article/1009113" target="_blank">aka d-motion pour les boomers</a>) pour &#8220;propager&#8221; le nouveau nom aux fichiers de la VM en question. Et pour ceux qui l&#8217;ignorait encore, <a href="http://www.yellow-bricks.com/2012/12/21/renaming-virtual-machine-files-using-svmotion-back/" target="_blank">cette feature était un bug jusqu&#8217;à la version 5.0 U2 d&#8217;ESXi</a>.</p>
<p style="text-align: justify;">Évidement, cela nécessite d&#8217;avoir <strong>un 2eme datastore</strong> (idéalement avec des performances identiques et la bonne volumétrie) pour faire l&#8217;aller-retour de la VM (ou un <a href="https://docs.vmware.com/en/vRealize-Operations-Manager/8.0/com.vmware.vcom.core.doc/GUID-82F8390B-8448-40DA-BFF1-30AB6166141D.html" target="_blank">Storage Pod</a>) <strong>ce qui n&#8217;est pas souvent le cas sur un cluster vSAN</strong> pour des raisons évidentes.</p>
<p style="text-align: center;"><img class="aligncenter" title="vSAN HCI Mesh" src="https://files.hypervisor.fr/img/VMware-vSAN-HCI-Mesh.png" alt="" width="498" height="302" /></p>
<p style="text-align: justify;">Jusqu&#8217;à maintenant, les seules solutions étaient de &#8230; ne rien faire ou de connecter un datastore NFS ponctuellement pour faire le svmotion. Mais en cherchant à faire du <strong><a href="https://core.vmware.com/resource/vmware-vsan-hci-mesh-tech-note#" target="_blank">HCI mesh</a></strong> en ligne de commande nous sommes tombé sur la solution (<a href="https://code.vmware.com/docs/12778/esxi-7-0-u1-esxcli-command-reference/namespace/esxcli_vsan.html" target="_blank">très discrètement documenté</a>) : <strong>esxcli vsan datastore add</strong> pour créer <strong>un 2eme datastore sur le vmdk namespace</strong>.<br />
<strong> </strong></p>
<p style="text-align: center;"><a href="http://download3.vmware.com/vmworld/2014/downloads/session-pdfs/STO1279_Final_US.pdf"><strong><img class="aligncenter" title="Architecting_Virtual_SAN" src="https://files.hypervisor.fr//img/Architecting_Virtual_SAN_6.2.2.008.1.png" alt="" width="519" height="398" /></strong></a></p>
<p style="text-align: justify;">Cette feature semble être apparu à partir de la version 6.7 U3 et est évidement accessible en PowerCLI également. Il suffit donc d&#8217;ajouter un &#8220;datastore&#8221; vSAN en précisant le nom et l&#8217;UUID de votre choix si vous le souhaitez. <strong>Il est nécessaire d&#8217;exécuter cette même commande sur tous les ESX du cluster avec le même nom <span style="color: #ff0000;"><span style="text-decoration: underline;">et le même UUID</span></span>.</strong></p>
<p style="text-align: center;"><a href="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/esxcli_vsan_datastore_add.png" target="_blank"><strong><img class="aligncenter" title="esxcli_vsan_datastore_add" src="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/esxcli_vsan_datastore_add.png" alt="" width="506" height="582" /></strong></a></p>
<blockquote>
<p style="text-align: justify;"><strong>Add a new datastore to the vSAN cluster</strong>. This operation is only allowed if vSAN is enabled on the host. In general, add should be done at cluster level. Across a vSAN cluster vSAN datastores should be in sync.</p>
</blockquote>
<p style="text-align: justify;">Voila ce que ça donne sur un cluster à 3 noeuds :</p>
<p style="text-align: center;"><a href="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/Get-EsxCli_vsan_datastore_add.png"><img class="aligncenter" src="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/Get-EsxCli_vsan_datastore_add.png" alt="" width="478" height="294" /></a></p>
<p style="text-align: justify;"><a href="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/vpx_vsandatastore2.png" target="_blank"><img class="aligncenter" src="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/vpx_vsandatastore2.png" alt="" width="487" height="330" /></a></p>
<p style="text-align: justify;"><a href="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/vsan_vm_storage_policies.png" target="_blank"><img class="aligncenter" src="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/vsan_vm_storage_policies.png" alt="" width="486" height="320" /></a>On peut donc maintenant faire notre svmotion aller-retour sans perte de performances.</p>
<p style="text-align: center;"><a href="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/vpx_svmotion.png" target="_blank"><img class="aligncenter" src="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/vpx_svmotion.png" alt="" width="444" height="260" /></a></p>
<p style="text-align: justify;">Une fois l&#8217;operation terminé on peut utiliser la commande &#8220;<strong>remove</strong>&#8221; en precisant le nom et l&#8217;UUID du datastore ou carrément la commande &#8220;<strong>clear</strong>&#8221; :</p>
<blockquote>
<p style="text-align: justify;"><strong>Remove all but the default datastore from the vSAN cluster</strong>. This operation is only allowed if vSAN is enabled on the host. In general, add should be done at cluster level. Across a vSAN cluster vSAN datastores should be in sync.</p>
</blockquote>
<p style="text-align: justify;">Et aucun risque de se rater, <strong>si une vm est toujours présente sur le datastore, vous aurez droit à une belle erreur</strong>. Après avoir fait du ménage, ça passe crème :</p>
<p style="text-align: center;"><a href="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/esxcli_vsan_datastore_clear.png" target="_blank"><img class="aligncenter" src="https://files.hypervisor.fr/img/Dual_vSAN_Datastores/esxcli_vsan_datastore_clear.png" alt="" width="478" height="313" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5949</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>#vExpert10 &amp; #Web30</title>
		<link>http://www.hypervisor.fr/?p=5915</link>
		<comments>http://www.hypervisor.fr/?p=5915#comments</comments>
		<pubDate>Thu, 08 Aug 2019 09:31:33 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[VMware]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[veeam]]></category>
		<category><![CDATA[SexiGraf]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5915</guid>
		<description><![CDATA[Time flies. Ce qu&#8217;il y a de génial avec cette expression anglaise américaine c&#8217;est qu&#8217;on visualise tout de suite un avion de chasse passer à mach 5 avec votre todo list. En tout cas, cela résume bien le silence d&#8217;un an entre ce post et le précédent qui avait pour vocation, lui  aussi, de célébrer [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;"><strong>Time flies</strong>. Ce qu&#8217;il y a de génial avec cette expression <span style="text-decoration: line-through;">anglaise</span> américaine c&#8217;est qu&#8217;on visualise tout de suite un avion de chasse passer à mach 5 avec votre todo list. En tout cas, cela résume bien le silence d&#8217;un an entre ce post et le précédent qui avait pour vocation, lui  aussi, de célébrer l&#8217;anniversaire de ce blog. Et de 11 !</p>
<p style="text-align: center;"><a href="http://www.hypervisor.fr/wp-content/uploads/2019/08/veeam_vanguard.jpg" title="veeam_vanguard" rel="lightbox[5915]"><img class="aligncenter size-full wp-image-5918" title="veeam_vanguard" src="http://www.hypervisor.fr/wp-content/uploads/2019/08/veeam_vanguard.jpg" alt="" width="395" height="178" /></a></p>
<p style="text-align: justify;">On va en profiter pour remercier VMware, Veeam et toute la communauté pour les nominations de <strong>vExpert</strong>, <strong>vExpert</strong> <strong>vSAN</strong> et <strong><span style="color: #008000;">Veeam Vanguard</span></strong> de cette année, c&#8217;est toujours un honneur. 10 étoiles ca commence à faire <img src='http://www.hypervisor.fr/wp-includes/images/smilies/icon_smile.gif' alt=':)' class='wp-smiley' /> </p>
<p style="text-align: center;"><a href="http://www.hypervisor.fr/wp-content/uploads/2019/08/vexpert_2019.png" title="vexpert_2019" rel="lightbox[5915]"><img class="aligncenter size-full wp-image-5919" title="vexpert_2019" src="http://www.hypervisor.fr/wp-content/uploads/2019/08/vexpert_2019.png" alt="" width="408" height="275" /></a></p>
<p style="text-align: justify;">Nous avons même <a href="https://blogs.vmware.com/virtualblocks/2019/03/08/vspeaking-podcast-episode-108-top-10-vmware-tools/?src=so_5c86ac27b7e2a&amp;cid=70134000001CTmC" target="_blank">eu droit à une &#8220;honorable mention&#8221; dans un des vSpeaking Podcast de VMware</a> pour <a href="http://www.sexigraf.fr" target="_blank">SexiGraf</a>. La classe <img class="superemotions" title="Cool" alt="Cool" border="0" src="http://www.hypervisor.fr/wp-includes/images/smilies/icon_cool.gif" /></p>
<p style="text-align: justify;">Et puisque c&#8217;est les 30 ans du <a href="https://web30.web.cern.ch" target="_blank">World Wide Web</a> ET de/du la/le <a href="https://www.theverge.com/2019/4/17/18311479/nintendo-game-boy-30th-anniversary-switch-gaming" target="_blank">Game Boy</a>, nous nous sommes permis :</p>
<p style="text-align: justify;"><a href="http://www.hypervisor.fr/wp-content/uploads/2019/08/web30_gameboy.png" title="web30_gameboy" rel="lightbox[5915]"><img class="aligncenter size-full wp-image-5917" title="web30_gameboy" src="http://www.hypervisor.fr/wp-content/uploads/2019/08/web30_gameboy.png" alt="" width="308" height="282" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5915</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>vExpert &amp; vExpert VSAN 2018</title>
		<link>http://www.hypervisor.fr/?p=5837</link>
		<comments>http://www.hypervisor.fr/?p=5837#comments</comments>
		<pubDate>Fri, 08 Jun 2018 10:32:27 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[VMware]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[vExpert]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5837</guid>
		<description><![CDATA[Comme chaque année, c&#8217;est avec honneur que nous rejoignons les rangs des VMware vExpert et, plus récemment, ceux du vExpert VSAN progam. Une fois de plus nous tenons à remerciez VMware et tout ceux qui nous soutiennent.

]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;">Comme chaque année, c&#8217;est avec honneur que nous rejoignons <a href="https://blogs.vmware.com/vmtn/2018/03/vexpert-2018-award-announcement.html" target="_blank">les rangs des VMware vExpert</a> et, plus récemment, <a href="https://blogs.vmware.com/vmtn/2018/06/vexpert-vsan-2018-announcement.html" target="_blank">ceux du vExpert VSAN progam</a>. Une fois de plus nous tenons à remerciez VMware et tout ceux qui nous soutiennent.</p>
<p style="text-align: center;"><img class="alignnone" src="http://files.hypervisor.fr/img/vExpert-2018-Badge-s.png" alt="" width="265" height="179" /><img class="alignnone" src="http://files.hypervisor.fr/img/vExpert-2018-VSAN-Badge-s.png" alt="" width="265" height="179" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5837</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>vExpert VSAN 2016</title>
		<link>http://www.hypervisor.fr/?p=5779</link>
		<comments>http://www.hypervisor.fr/?p=5779#comments</comments>
		<pubDate>Tue, 23 Aug 2016 16:45:32 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[VMware]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[vExpert]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5779</guid>
		<description><![CDATA[Depuis quelques jours, je fais parti, ainsi que mon très cher &#8220;confrère&#8221; et ami Frédéric, du cercle très fermé des vExpert VSAN 2016.
C&#8217;est un honneur que nous devons en grande parti au travail effectué sur SexiGraf ainsi qu&#8217;à la communauté qui nous a largement soutenu dans notre démarche.
Merci à tous pour votre implication, vos retours [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;"><a href="https://blogs.vmware.com/vmtn/2016/08/vexpert-2016-vsan-announcement.html" target="_blank">Depuis quelques jours</a>, je fais parti, ainsi que mon très cher &#8220;confrère&#8221; et ami <a href="http://www.vmdude.fr/news/vexpert-vsan-2016/" target="_blank">Frédéric</a>, du cercle très fermé des <strong>vExpert VSAN 2016</strong>.</p>
<p style="text-align: justify;">C&#8217;est un honneur que nous devons en grande parti au travail effectué sur <a href="http://www.sexigraf.fr/vsan-sexipanels/" target="_blank">SexiGraf</a> ainsi qu&#8217;à la communauté qui nous a largement soutenu dans notre démarche.</p>
<p style="text-align: justify;">Merci à tous pour votre implication, vos retours et vos critique qui nous permettent de faire avancer cet outil dans la bonne direction!</p>
<p><img class="aligncenter" src="http://files.hypervisor.fr/img/vExpert_vSAN_2016_s.jpg" alt="" width="256" height="169" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5779</wfw:commentRss>
		<slash:comments>4</slash:comments>
		</item>
		<item>
		<title>VSAN SwapThickProvisionDisabled OneLiner</title>
		<link>http://www.hypervisor.fr/?p=5766</link>
		<comments>http://www.hypervisor.fr/?p=5766#comments</comments>
		<pubDate>Tue, 23 Aug 2016 16:30:30 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[VMware]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[overcommit]]></category>
		<category><![CDATA[PowerCLI]]></category>
		<category><![CDATA[powershell]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5766</guid>
		<description><![CDATA[Alors que nous en rêvions depuis 10 ans pour VMFS, VMware a introduit dans VSAN 6.2 la possibilité de &#8220;thin provisioner&#8221; la swap des VM :
In Virtual SAN 6.2, we introduced an advanced host setting called SwapThickProvisionDisabled, when enabled, removes the space reservation for .vswp files.
Une preuve de plus, s&#8217;il en fallait, que la bataille [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;">Alors que nous en rêvions depuis 10 ans pour VMFS, <a href="https://blogs.vmware.com/virtualblocks/2016/02/24/vsan62-powercli-sparse-vswp/#respond" target="_blank">VMware a introduit dans VSAN 6.2 la possibilité de &#8220;thin provisioner&#8221; la swap des VM</a> :</p>
<blockquote><p>In Virtual SAN 6.2, we introduced an advanced host setting called SwapThickProvisionDisabled, when enabled, removes the space reservation for .vswp files.</p></blockquote>
<p style="text-align: justify;">Une preuve de plus, s&#8217;il en fallait, que la bataille du SDS/HCI est rude jusqu&#8217;à en rogner ses best practices. En effet, nous rappelons à ceux qui auraient un trou de mémoire que placer le fichier de swap d&#8217;une VM sur un stockage &#8220;thin provisioné&#8221; va à l&#8217;encontre de toutes <a href="http://www.vmware.com/pdf/Perf_Best_Practices_vSphere5.0.pdf" target="_blank">les bonnes règles de gestion</a> et <a href="https://pubs.vmware.com/vsphere-55/topic/com.vmware.vsphere.resmgmt.doc/GUID-AC40823A-695B-438A-A8F2-4B7C51A0D014.html" target="_blank">d&#8217;overcommit</a>.</p>
<blockquote><p><strong> Do not store swap files on thin-provisioned LUNs</strong>. Running a virtual machine with a swap file that is stored on a thin-provisioned LUN can cause swap file growth failure, which can lead to termination of the virtual machine.</p></blockquote>
<blockquote><p>Regardless of the storage type or location used for the regular swap file, for the best performance, and to avoid the possibility of running out of space, <strong>swap files should not be placed on thin-provisioned storage</strong>.</p></blockquote>
<p>Qu&#8217;importe, ca nous arrange bien aussi et pour l&#8217;occasion nous avons fait peter un petit oneliner pour fixer la bonne valeur :</p>
<pre class="brush: powershell; title: ; notranslate">Get-VMHost|%{(Get-EsxCli -VMHost $_).system.settings.advanced.set($null,&quot;1&quot;,&quot;/VSAN/SwapThickProvisionDisabled&quot;,$null)}</pre>
<p>Et un autre pour vérifier que c&#8217;est bien appliqué :</p>
<pre class="brush: powershell; title: ; notranslate">Get-VMHost|%{(Get-EsxCli -VMHost $_).system.settings.advanced.list($null,&quot;/VSAN/SwapThickProvisionDisabled&quot;,$null)}</pre>
<p style="text-align: center;"><a href="http://files.hypervisor.fr/img/SwapThickProvisionDisabled.png"><img class="aligncenter" src="http://files.hypervisor.fr/img/SwapThickProvisionDisabled.png" alt="" width="526" height="249" /></a></p>
<p style="text-align: left;">Avec un petit coup de <a href="http://www.sexigraf.fr/vsan-sexipanels/#vsan-space-usage-report" target="_blank">SexiGraf </a>pour monitorer le tout, on est bon :</p>
<p style="text-align: center;"><a href="http://files.hypervisor.fr/img/VSAN_SwapThickProvisionDisabled.png" target="_blank"><img class="aligncenter" src="http://files.hypervisor.fr/img/VSAN_SwapThickProvisionDisabled.png" alt="" width="515" height="275" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5766</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>ftp.dell.com direct iDRAC update &#8211; MAJ</title>
		<link>http://www.hypervisor.fr/?p=5696</link>
		<comments>http://www.hypervisor.fr/?p=5696#comments</comments>
		<pubDate>Sun, 03 Apr 2016 23:04:53 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[Hardware]]></category>
		<category><![CDATA[Tips & Tricks]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[Dell]]></category>
		<category><![CDATA[iDRAC]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5696</guid>
		<description><![CDATA[MAJ 19/11/2021 : Dell a coupé le service ftp à partir de février 2021 mais il est possible de passer en https pour les idrac qui le supporte (une maj est parfois nécessaire) :
Dell EMC has retired ftp.dell.com and transitioned exclusively to a global downloads site with regional hosted repositories .Feb 21, 2021


MAJ 27/07/2016 : [...]]]></description>
			<content:encoded><![CDATA[<p><em><span style="color: #ff0000;">MAJ 19/11/2021</span> : Dell a coupé le service ftp à partir de février 2021 mais <a href="https://www.dell.com/support/kbdoc/en-us/000132986/dell-emc-catalog-links-for-poweredge-servers" target="_blank">il est possible de passer en https pour les idrac qui le supporte</a> (une maj est <em>parfois </em>nécessaire) :</em></p>
<blockquote><p>Dell EMC has retired ftp.dell.com and transitioned exclusively to a global downloads site with regional hosted repositories .Feb 21, 2021</p></blockquote>
<p style="text-align: center;"><em><a href="https://files.hypervisor.fr/img/ftp_dell_com/idrac_https.png" target="_blank"><img class="aligncenter" src="https://files.hypervisor.fr/img/ftp_dell_com/idrac_https.png" alt="" width="476" height="330" /></a><br />
</em></p>
<p><em><span style="color: #ff0000;">MAJ 27/07/2016</span> : <a href="https://twitter.com/mindflux/status/753976102394093569" target="_blank">Il semblerait</a> que la valeur &#8220;<strong>/catalog</strong>&#8221; pour la <strong>Catalog Location</strong> offre des versions nettement plus up2date.</em></p>
<p>Parmi <a href="http://www.dell.com/support/article/us/en/19/SLN293301/en" target="_blank">les nombreuses méthodes pour upgrader les firmware des composants d&#8217;un serveur Dell</a>, il y en une qui nous intéressait beaucoup mais que nous n&#8217;arrivions pas à faire fonctionner : <a href="http://en.community.dell.com/techcenter/extras/m/white_papers/20438129/download" target="_blank">la méthode <strong>ftp.dell.com</strong></a></p>
<blockquote><p>The repository could either be <strong>ftp.dell.com</strong> or a user generated repository on the local network share.</p></blockquote>
<p style="text-align: justify;">Sur les serveurs Dell relativement récents, il est en effet possible de &#8220;stager&#8221; et &#8220;scheduler&#8221; toutes les updates matérielles possibles directement depuis l&#8217;iDRAC en live depuis le ftp Dell. Et <strong>depuis la version v.2.21.21.21 les firmwares des HDD/SSD sont complètement supportés</strong> même sur un contrôleur en mode HBA (passthrough).</p>
<p style="text-align: justify;">Malheureusement impossible de trouver dans les docs Dell les informations nécessaires pour y arriver :</p>
<p style="text-align: center;"><a href="http://files.hypervisor.fr/img/ftp_dell_com/idrac_ftp_ko.png" title="idrac_ftp_ko" rel="lightbox[5696]"><img class="aligncenter size-medium wp-image-5701" title="idrac_ftp_ko" src="http://www.hypervisor.fr/wp-content/uploads/2016/04/idrac_ftp_ko-299x242.png" alt="" width="299" height="242" /></a></p>
<p style="text-align: left;">Mais ça c’était avant de connaitre Lionel, Onsite System Engineer chez Dell, qui nous a donné le trick :</p>
<p style="text-align: left;"><a href="http://files.hypervisor.fr/img/ftp_dell_com/idrac_ftp_ok.png" title="idrac_ftp_ok" rel="lightbox[5696]"><img class="aligncenter size-medium wp-image-5712" title="idrac_ftp_ok" src="http://www.hypervisor.fr/wp-content/uploads/2016/04/idrac_ftp_ok-300x274.png" alt="" width="300" height="274" /></a></p>
<p style="text-align: center;">
<blockquote><p>FTP Address : <strong>ftp.dell.com</strong><br />
User Name : <strong>anonymous</strong><br />
Password : <strong>user@domain.com</strong><br />
Catalog Location : <strong>/</strong><br />
Catalog Filename : <strong>Catalog.xml.gz</strong></p></blockquote>
<p style="text-align: left;">D’après le serveur ftp de Dell, le password doit etre un e-mail : &#8220;<strong>Anonymous access allowed, send identity (e-mail name) as password.</strong>&#8220;</p>
<p style="text-align: left;">Ensuite vous rebootez quand vous voulez et les patchs sont appliqués (rapidement) par le Lifecycle Controler :</p>
<p style="text-align: center;"><a href="http://files.hypervisor.fr/img/ftp_dell_com/idrac_ftp_ok_install.png" title="idrac_ftp_ok_install" rel="lightbox[5696]"><img class="alignnone size-thumbnail wp-image-5714" title="idrac_ftp_ok_install" src="http://www.hypervisor.fr/wp-content/uploads/2016/04/idrac_ftp_ok_install-150x150.png" alt="" width="150" height="150" /></a> <a href="http://files.hypervisor.fr/img/ftp_dell_com/idrac_ftp_ok_reboot.png" title="idrac_ftp_ok_reboot" rel="lightbox[5696]"><img class="alignnone size-thumbnail wp-image-5715" title="idrac_ftp_ok_reboot" src="http://www.hypervisor.fr/wp-content/uploads/2016/04/idrac_ftp_ok_reboot-150x150.png" alt="" width="150" height="150" /></a> <a href="http://files.hypervisor.fr/img/ftp_dell_com/idrac_ftp_ok_lifecycle.png" title="idrac_ftp_ok_lifecycle" rel="lightbox[5696]"><img class="alignnone size-thumbnail wp-image-5716" title="idrac_ftp_ok_lifecycle" src="http://www.hypervisor.fr/wp-content/uploads/2016/04/idrac_ftp_ok_lifecycle-150x150.png" alt="" width="150" height="150" /></a> <a href="http://files.hypervisor.fr/img/ftp_dell_com/idrac_ftp_ok_flash.png" title="idrac_ftp_ok_flash" rel="lightbox[5696]"><img class="alignnone size-thumbnail wp-image-5717" title="idrac_ftp_ok_flash" src="http://www.hypervisor.fr/wp-content/uploads/2016/04/idrac_ftp_ok_flash-150x150.png" alt="" width="150" height="150" /></a></p>
<p style="text-align: left;">Merci Lionel <img src='http://www.hypervisor.fr/wp-includes/images/smilies/icon_wink.gif' alt=';)' class='wp-smiley' /> </p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5696</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Monitor, like a boss.</title>
		<link>http://www.hypervisor.fr/?p=5604</link>
		<comments>http://www.hypervisor.fr/?p=5604#comments</comments>
		<pubDate>Thu, 22 Oct 2015 19:34:43 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[Performance]]></category>
		<category><![CDATA[VMware]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[ZFS]]></category>
		<category><![CDATA[cacti]]></category>
		<category><![CDATA[carbon]]></category>
		<category><![CDATA[grafana]]></category>
		<category><![CDATA[graphite]]></category>
		<category><![CDATA[monitoring]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5604</guid>
		<description><![CDATA[Si comme nous, vous cherchiez une solution de monitoring cluster centric, ne cherchez plus. Nous l&#8217;avons faites pour vous :

Très loin des dashboard cacti fastidieux à réaliser et limités en scalabilité, nous avons voulu une appliance la simple possible : deploy, add vcenter, relax!

]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;">Si comme nous, vous cherchiez une solution de monitoring cluster centric, ne cherchez plus. <strong><a href="http://www.sexigraf.fr/" target="_blank">Nous l&#8217;avons faites pour vous</a> </strong>:</p>
<p style="text-align: center;"><a href="http://www.sexigraf.fr/"><img class=" aligncenter" title="Enter SexiGraf" src="http://files.hypervisor.fr/img/SexiGraf_Enter.png" alt="" width="521" height="353" /></a></p>
<p style="text-align: justify;">Très loin <a href="https://github.com/rschitz/vCacti" target="_blank">des dashboard cacti fastidieux à réaliser et limités en scalabilité</a>, nous avons voulu une appliance la simple possible : <strong>deploy</strong>, <strong>add vcenter</strong>, <strong>relax</strong>!</p>
<p style="text-align: center;"><a href="http://files.sexigraf.fr/seximeetup/sexigraf/"><img class="aligncenter" src="http://files.sexigraf.fr/seximeetup/sexigraf/img/hannibal.png" alt="" width="359" height="443" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5604</wfw:commentRss>
		<slash:comments>17</slash:comments>
		</item>
		<item>
		<title>visor-thin &amp; vsantraces</title>
		<link>http://www.hypervisor.fr/?p=5592</link>
		<comments>http://www.hypervisor.fr/?p=5592#comments</comments>
		<pubDate>Sat, 10 Oct 2015 21:13:14 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[Hardware]]></category>
		<category><![CDATA[Kb]]></category>
		<category><![CDATA[Tips & Tricks]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[scratch]]></category>
		<category><![CDATA[SD card]]></category>
		<category><![CDATA[stateless]]></category>
		<category><![CDATA[support]]></category>
		<category><![CDATA[usb]]></category>
		<category><![CDATA[VisorFS]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5592</guid>
		<description><![CDATA[Sur un cluster VSAN composé d&#8217;ESXi 6.0 bootant sur des cartes SD, nous avons récemment été confronté à ces erreurs :
&#60;14&#62;2015-09-04T22:03:39.616Z esx.vmware.com vobd:  [VisorfsCorrelator] 2274728093499us: [esx.problem.visorfs.ramdisk.full] The ramdisk &#8216;vsantraces&#8217; is full.  As a result, the file /vsantraces/vsantraces&#8211;2015-09-04T21h31m52s079.gz could not be written.
[...]
&#60;14&#62;2015-09-04T21:00:53.492Z esx.vmware.com vobd:  [VisorfsCorrelator] 2269273677949us: [vob.visorfs.ramdisk.full] Cannot extend visorfs file /vsantraces/vsantraces&#8211;2015-09-04T19h34m10s776.gz because its ramdisk (vsantraces) [...]]]></description>
			<content:encoded><![CDATA[<p>Sur un <strong>cluster VSAN composé d&#8217;ESXi 6.0 bootant sur des cartes SD</strong>, nous avons récemment été confronté à ces erreurs :</p>
<blockquote><p>&lt;14&gt;2015-09-04T22:03:39.616Z esx.vmware.com vobd:  [VisorfsCorrelator] 2274728093499us: [esx.problem.visorfs.ramdisk.full] The ramdisk &#8216;vsantraces&#8217; is full.  As a result, the file /vsantraces/vsantraces&#8211;2015-09-04T21h31m52s079.gz could not be written.</p>
<p>[...]</p>
<p>&lt;14&gt;2015-09-04T21:00:53.492Z esx.vmware.com vobd:  [VisorfsCorrelator] 2269273677949us: [vob.visorfs.ramdisk.full] Cannot extend visorfs file /vsantraces/vsantraces&#8211;2015-09-04T19h34m10s776.gz because its ramdisk (vsantraces) is full.</p></blockquote>
<p style="text-align: justify;">La cause de ce problème est assez simple : <a href="http://www.hypervisor.fr/?p=2405"><strong>booter ESXi via USB ou SD card = visor-thin = partition /scratch dans la RAM</strong></a>. Et quand vous n&#8217;avez pas de scratch persistante, <strong>la partition /vsantraces est configurée par défaut à 300MB</strong> comme vous pouvez le constater dans /etc/vmware/vsan/vsantraced.conf :</p>
<blockquote><p># Ramdisk size in MB (do not increase over 300MB without a matching increase<br />
# to coredump size).<br />
#VSANTRACED_RAMDISK_SIZE=300</p></blockquote>
<p>Or comme l&#8217;explique Cormac dans son post <a href="http://cormachogan.com/2015/02/24/vsan-considerations-when-booting-from-usbsd/">VSAN considerations when booting from USB/SD</a> :</p>
<blockquote><p><strong>VSAN traces require ~500MB of disk space.</strong></p></blockquote>
<p style="text-align: justify;">Aprés quelques échanges avec le support VMware, il nous a été confirmé qu&#8217;il était possible et <strong>supporté</strong> de changer la taille de cette partition en modifiant vsantraced.conf, ce que nous avons pu tester et valider en l’augmentant à 500MB pour mettre fin aux erreurs :</p>
<p style="text-align: center;"><img class="aligncenter" src="http://files.hypervisor.fr/img/VSAN/vsantraces_500MB.png" alt="" width="491" height="203" /></p>
<p>GSS nous a cependant mis en garde :</p>
<blockquote><p>Just be aware that if you do so, you also must increase coredump size by the same value.</p></blockquote>
<p>Il nous a également fallu <a href="http://kb.vmware.com/kb/1010611"><strong>rediriger le workingdir de la commande vm-support</strong></a> (lorsque nous en avons besoin) pour éviter l&#8217;erreur suivante :</p>
<blockquote><p>IOError: [Errno 28] No space left on device</p></blockquote>
<p>Une autre info interessante sur le sujet : <a href="http://cormachogan.com/2015/08/14/handling-vsan-trace-files-when-esxi-boots-from-a-flash-device/">Handling VSAN trace files when ESXi boots from a flash device</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5592</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>VsanHostDecommissionMode en PowerCLI</title>
		<link>http://www.hypervisor.fr/?p=5581</link>
		<comments>http://www.hypervisor.fr/?p=5581#comments</comments>
		<pubDate>Sat, 08 Aug 2015 00:03:51 +0000</pubDate>
		<dc:creator>NiTRo</dc:creator>
				<category><![CDATA[Tips & Tricks]]></category>
		<category><![CDATA[VMware]]></category>
		<category><![CDATA[VSAN]]></category>
		<category><![CDATA[esxcli]]></category>
		<category><![CDATA[Get-EsxCli]]></category>
		<category><![CDATA[PowerCLI]]></category>
		<category><![CDATA[powershell]]></category>

		<guid isPermaLink="false">http://www.hypervisor.fr/?p=5581</guid>
		<description><![CDATA[Pour les 7 ans d&#8217;Hypervisor.fr (si,si, c&#8217;est aujourd&#8217;hui) nous vous offrons un petit onliner pour mettre en maintenance un des nœuds de votre cluster VSAN en PowerCLI, dans la lignée de nos précédents posts &#8220;vSphere sans le webclient&#8221;.
Nous étions parti pour utiliser le script disponible sur VSANTeam.info mais il est malheureusement faux car il n&#8217;inclus pas l&#8217;objet [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;">Pour les 7 ans d&#8217;<strong>Hypervisor.fr</strong> (<a href="http://www.hypervisor.fr/?p=1" target="_blank">si,si, c&#8217;est aujourd&#8217;hui</a>) nous vous offrons un petit onliner pour <strong>mettre en maintenance un des nœuds de votre cluster VSAN en PowerCLI</strong>, dans la lignée de nos précédents posts &#8220;vSphere sans le webclient&#8221;.</p>
<p style="text-align: justify;">Nous étions parti pour utiliser le script disponible sur <a href="http://vsanteam.info/maintenance-mode-using-powercli/" target="_blank">VSANTeam.info</a> mais il est malheureusement faux car il n&#8217;inclus pas l&#8217;objet <a href="http://pubs.vmware.com/vsphere-60/topic/com.vmware.wssdk.apiref.doc/vim.vsan.host.DecommissionMode.ObjectAction.html" target="_blank">VsanHostDecommissionModeObjectAction</a> et donc <strong>le mode &#8220;ensureObjectAccessibility&#8221; est utilisé par défaut</strong>. Donc pour pouvoir utiliser le mode &#8220;evacuateAllData&#8221; ou &#8220;noAction&#8221; c&#8217;est comme ça qu&#8217;on fait :</p>
<pre class="brush: powershell; title: ; notranslate">Get-View -ViewType HostSystem -Filter @{&quot;Name&quot; = &quot;esx.vmware.com&quot; }|?{!$_.Runtime.InMaintenanceMode}|%{$_.EnterMaintenanceMode(0, $false, (new-object VMware.Vim.HostMaintenanceSpec -Property @{vsanMode=(new-object VMware.Vim.VsanHostDecommissionMode -Property @{objectAction=[VMware.Vim.VsanHostDecommissionModeObjectAction]::NoAction})}))}</pre>
<p>Sinon vous pouvez aussi le faire avec Get-EsxCli en vous inspirant <a href="http://www.virtuallyghetto.com/2014/07/quick-tip-steps-to-shutdownstartup-vsan-cluster-wvcenter-running-on-vsan-datastore.html" target="_blank">du post de William</a>.</p>
<p style="text-align: center;"><img class="aligncenter" src="http://files.hypervisor.fr/img/vSAN.png" alt="" width="349" height="260" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hypervisor.fr/?feed=rss2&amp;p=5581</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>